ADSS cables are suitable for installation on structures for both distribution and transmission lines. Standard jacket materials have a space potential exposure compatibility up to 12 kV. If the cable is installed on structures with medium to high voltage transmission lines, it is recommended that electrical stress analysis be performed to determine the appropriate cable placement on the structure to insure that the e-field space potential is <12kV.
Features
1. Can be installed without shutting off the power;
2. Excellent AT performance, The maximum inductive at the operating point of AT sheath can reach 25kV;
3. Light weight and small diameter reducing the load caused by ice and wind and the load on towers and backprops;
4. Large span lengths and the largest span is over 1000m;
5. Good performance of tensile strength and temperature;
6. The design life span is 30 years.
Do I need Wi-Fi if I have fibre?
Fiber Type | Attenuation | 1310nm MFD (Mode Field Diameter) | Cable Cut-off Wavelength λcc(nm) | |
@1310nm(dB/KM) | @1550nm(dB/KM) | |||
G652D | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A1 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A2 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G655 | ≤0.4 | ≤0.23 | (8.0-11)±0.7 | ≤1450 |
Fiber Count | Cable Diameter (mm) ±0.5 | Cable Weight (kg/km) | 100m Span Tensile Strength (N) | Crush Resistance (N/100mm) | Bending Radius (mm) | |||
Long Term | Short Term | Long Term | Short Term | Static | Dynamic | |||
2-12 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
24 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
36 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
48 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
72 | 10 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
96 | 11.4 | 100 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
144 | 14.2 | 150 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
Power Line, dielectric needed or large span communication line.
Self-supporting aerial.
Temperature Range | ||
Transportation | Installation | Operation |
-40℃~+70℃ | -5℃~+45℃ | -40℃~+70℃ |
DL/T 788-2016
Fibercable puls cables are coiled on bakelite, wooden, or ironwood drums. During transportation, the right tools should be used to avoid damaging the package and to handle them with ease. Cables should be protected from moisture, kept away from high temperatures and fire sparks, protected from over-bending and crushing, and protected from mechanical stress and damage. It is not allowed to have two lengths of cable in one drum, and both ends should be sealed. The two ends should be packed inside the drum, and a reserve length of cable not less than 3 meters should be provided.