ADSS cable is loose tube stranded. Fibers, 250μm , are positioned into a loose tube made of high modulus plastics. The tubes are filled with a water-resistant filling compound. The tubes (and fillers) are stranded around a FRP (Fiber Reinforced Plastic) as a non-metallic central strength member into a compact and circular cable core. After the cable core is filled with filling compound. it is covered with thin PE (polyethylene) inner sheath. After stranded layer of aramid yarns are applied over the inner sheath as strength member, the cable is completed with PE or AT (anti-tracking) outer sheath.
·Characteristics
· Can be installed without shutting off the power
· Excellent AT performance, The maximum inductive at the operating point of AT sheath can reach 25kV
· Light weight and small diameter reducing the load caused by ice and wind and the load on towers
and backprops
· Large span lengths and the largest span is over 1000m
· Good performance of tensile strength and temperature
· The design life span is 30 years
·Application
The actual status of overhead power lines is taken into full consideration when ADSS cable is being designed. For overhead power lines under 110kV, PE outer sheath is applied. FOR power lines equal to or over 110kV, AT outer sheath is applied. The dedicate design of aramid quantity and stranding process can satisfy the demand on various spans.
Fiber Type | Attenuation | 1310nm MFD (Mode Field Diameter) | Cable Cut-off Wavelength λcc(nm) | |
@1310nm(dB/KM) | @1550nm(dB/KM) | |||
G652D | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A1 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G657A2 | ≤0.36 | ≤0.22 | 9.2±0.4 | ≤1260 |
G655 | ≤0.4 | ≤0.23 | (8.0-11)±0.7 | ≤1450 |
Fiber Count | Cable Diameter (mm) ±0.5 | Cable Weight (kg/km) | 100m Span Tensile Strength (N) | Crush Resistance (N/100mm) | Bending Radius (mm) | |||
Long Term | Short Term | Long Term | Short Term | Static | Dynamic | |||
2-12 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
24 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
36 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
48 | 9.8 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
72 | 10 | 80 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
96 | 11.4 | 100 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
144 | 14.2 | 150 | 1000 | 2500 | 300 | 1000 | 10D | 20D |
Power Line, dielectric needed or large span communication line.
Self-supporting aerial.
Temperature Range | ||
Transportation | Installation | Operation |
-40℃~+70℃ | -5℃~+45℃ | -40℃~+70℃ |
DL/T 788-2016
Fibercable puls cables are coiled on bakelite, wooden, or ironwood drums. During transportation, the right tools should be used to avoid damaging the package and to handle them with ease. Cables should be protected from moisture, kept away from high temperatures and fire sparks, protected from over-bending and crushing, and protected from mechanical stress and damage. It is not allowed to have two lengths of cable in one drum, and both ends should be sealed. The two ends should be packed inside the drum, and a reserve length of cable not less than 3 meters should be provided.